Summary: The A-mod controls and seal kit are obsolete and no longer available from Parker. They have been replaced with the new B-mod design version of the Pressure Limiter, Load Sense, and Pilot Operated Pressure Limiter.
Applies to: Clients who have Parker P1 or PD series pumps with the obsolete A-mod controls and want to replace them with the updated B-mod version.
FINAL ACCEPTANCE CRITERIA
- Understand that the A-mod controls are already obsolete.
- The replacement are the B-mod controls.
- Understand why an adapter block is needed.
- Identify the correct adapter part number based on the pump's direction of rotation.
TECHNICAL BULLETIN
The A-mod and B-mod controls do not have the same mounting design. The A-mod uses a 4-port pattern and the B-mod uses a 5-port pattern. This is why the B-mod control will not fit directly on an A-mod pump. To use the B-mod control, an adapter block must be installed between the pump and the control. Parker has two versions of the adapter, depending on whether the pump is CW (S2E-20301-5) or CCW (S2E-20302-5).